OC-FCa™ Reagent

Fecal Calprotectin Test

OC-FCa™ Reagent

OC-FCa Reagent is for quantitative measurement of calprotectin in faces using automated fecal test analyzer, OC-SENSOR R70, OC-SENSOR PLEDIA and OC-SENSOR Ceres. The same OC-Auto Sampling Bottle 3 & 4 used for FIT can also be used for fecal calprotectin (FCa) testing. OC-Auto Sampling Bottle 3 & 4 and OC-SENSOR are widely used in over 50 countries worldwide.

Featured Publications

Shin E, Seo JD, Shim HS, et al. Clinical Comparison of OC-Sensor Pledia and Phadia 250 for Fecal Calprotectin Testing. Diagnostics (Basel). 2024 Nov 7;14(22):2490. PubMed >

O'Driscoll S, Piggott C, Benton SC. Evaluation of a faecal calprotectin method using the OC-SENSOR PLEDIA. Clin Chem Lab Med. 2022 Mar 14;60(6):901-906. PubMed >

Butenas J, Ayling RM. Clinical evaluation of the OC-Sensor Pledia calprotectin assay. Clin Chem Lab Med. 2022 Sep 12;60(11):1780-1785.

PubMed >

Advantages of OC-FCa

OC-FCa can provide significant improvement in below three points regarding productivity;

Point 1. For patients, use the same OC-Auto Sampling Bottle 3 & 4, as fecal immunochemical test (FIT). Only one-time collection by the patient with lower gastrointestinal symptoms.

Point 2 . For laboratories, no specimen extraction required after collecting stool by patients.

Point 3. For doctors, getting the result of both FIT and Calprotectin in a short time, help predict the risk of colorectal cancer, advanced adenoma, inflammatory bowel disease, etc.

  • There are other advantages as follows;
  1. The wide measurement range (up to 2,720 μg/g) reduces the workload of retesting samples with high concentrations.
  2. OC-Auto Sampling Bottle 3 can be stored at room temperature (1-30 °C). It can be provided to patients in the same way as vacant specimen containers.
  3. Reagents, Control and Calibrator are ready-to-use (required to be refrigerated).

Principle of Latex agglutination immunoturbidimetry

Latex Reagent for OC-SENSOR series is an immunoassay test reagent and used together with an automatic analyzer for measurement of calprotectin in stool. Latex Reagent contains the latex particles coated with anti-human calprotectin antibodies for optical measurement of the latex agglutination reaction.

The change in absorbance per unit time resulting from the latex agglutination reaction is proportional to the concentration of calprotectin in the sample. A dose response curve of the absorbance unit (OD) vs. concentration is generated using the results obtained from the calibrators. The concentration of calprotectin in the patient sample is determined from this curve.

Product List

Code No.

Product Name

Unit

Remarks

V-PH09

OC-FCa Reagent

Latex   2 x 8mL

Buffer 2 x 15mL

for OC-SENSOR R70 and OC-SENSOR Ceres

V-PH08

OC-SENSOR Sample Diluent

2 x 20 mL

V-PH12

OC-FCa Calibrator

6 x 1 mL

for OC-SENSOR R70, OC-SENSOR Ceres and OC-SENSOR PLEDIA

V-PH13

OC-FCa Control LV1

2 x 5 mL

V-PH14

OC-FCa Control LV2

2 x 5 mL

V-PH15

OC-FCa Control LV3

2 x 5 mL

V-PH11 OC-FCa Reagent

Latex   2 x 8 mL

Buffer 2 x 15 mL  

for OC-SENSOR PLEDIA
V-PH19 OC-SENSOR Sample Diluent 3 x 45 mL

・For in vitro diagnostic use.
・CE-marked under IVDR and available in the EU. Availability may vary by country.

Product Series

Related Pages

Contact us

  Select a Topic
  First Name
  Last Name
  Organization
  Email Address
  Country
  Address
  Message
  Privacy Policy